Flash Purification Systems
Routine Flash purification :
- Small but mighty
- Maximum flowrate of up to 300 ml/min @ max. 20 bar
- Flow rate accuracy +/- 2% over 20-250mL/min @ 5-16bar
- Quaternary gradient valve – step: +/- 0.1%
- Suitable for a comprehensive range of columns
- 4G to 800G Flash Columns for Routine Purification
- RFID: Universal: non-restrictive system
- Load&Go technology: Automatic injection valve for
- DryLoad with pack_ULTRA
- Flow rate accuracy collector: +/- 2%
- 15’’ touchscreen
puriFlash® XS 520 Plus
- Ultra Performance Flash Purification:
- Maximum flow rate of up to 300ml/min @ max. 20bar
- Flow rate accuracy +/- 2% over 20-250mL/min @ 5-16bar
- Quaternary gradient valve – step: +/- 0.1%
- Easily use columns in formats F0004 to F0800 optimum flow rate
- RFID Dry-Load & column
- Universal: non-restrictive system
- Load&Go technology: Automatic injection valve for DryLoad
- Flow rate accuracy collector: +/- 2%
- iELSD Detection
- Pump, fraction collector, integrated detectors, valves & columns leak detection
- Solvents and waste level monitoring
- 15’’ touchscreen
puriFlash® 5.020
- Maximum flow rate of up to 250ml/min @ max. 50bar
- Flow rate accuracy +/- 2% over 20-200mL/min @ 5-40bar
- Quaternary gradient valve – step: +/- 0.1%
- RFID readers for flash and prep columns, loops and dryloads for each position
iELSD Detection - Pump, fraction collector, integrated detectors, valves & columns leak detection
- Solvents and waste level monitoring
- Upgradable with MS
- Upgradable with AS, 2nd fraction collector, injection pump
- 15’’ touchscreen
puriFlash® 5.35-XL
- Process Flash Purification
- Your ideal tool for high-throughput purification of raw product
- Big brother to the puriFlash XS 520 Plus.
- Can purify a small to large amount of your product of interest with minimal runs
- Maximum flow rate of up to 400 ml/min @ max. 35 bar
- Quaternary gradient valve – step: +/- 0.1%
- RFID: Universal, non-restrictive system RFID Dry-Load & column w/ pack-Process
- Pump, fraction collector, integrated detectors, valves & columns leak detection
- 15’’ touchscreen
puriFlash® 5.015-
- Maximum flow rate of up to 825ml/min @ max. 15 bar
- Quaternary gradient valve – step: +/- 0.1%
- RFID: Universal, non-restrictive system RFID Dry-Load & column w/ pack-Process
- Pump, fraction collector, integrated detectors, valves & columns leak detection
- Solvents and waste level monitoring
- Production continuity on the same device, regardless of the scale-up factor
- 15’’ touchscreen